AEROSPACE |
|
Products |
| |
Series 2000
|
Transducer, Frequency Outputs,
Absolute or Gauge |
| |
Series 3000
|
Transducer, Frequency Outputs,
Absolute |
|
|
| |
Series 4000
|
Transducer, Frequency Outputs,
Absolute |
| |
Series 5300
|
Transducer, Frequency Outputs,
Differential Pressure |
|
| |
Series 1000 |
Transmitter, RS-232 & RS-485
Output, Absolute, Gauge or Differential |
| |
Series 6000
|
Transmitter, RS232 & RS-485
Output, Absolute or Gauge |
| |
Series 9000
|
Transmitter, RS-232 & RS-485
Output, Absolute Pressure |
| |
Model 745
|
High Accuracy Laboratory Pressure
Standard |
|
| |
Model 765
|
High Accuracy Portable
Pressure Standard |
| |
Barometers |
|
| |
Accessories |
|
| |
|
|
|
Applications |
|
Digiquartz®
Pressure Transducers have been used for decades in
Flight
Applications including air data computers, missile testing,
engine pressure ratio transmitters, and digital electronic engine
control systems. Ground uses include windtunnel instrumentation,
air data test sets, and
Altimeter Setting
Indicators. These high resolution transducers are the key
sensors in an
extremely accurate fuel measurement gauging system on
geosynchronous communication satellites. The Model 760-16B is the
standard field calibrator used by the FAA to test airport
altimeter systems.
Frequency output transducers can be connected to an
intelligent
electronic card to make a system capable of RS-232 and RS-485
operation.
A two line
digital display the Model 715, can be connected to all new
Paroscientific transmitters with RS-232 and RS-485 output, to
provide digital readout of pressure, temperature, engineering
units, overpressure warning, tare indication, user defined
messages and a horizontal bar graph showing percentage of
full-scale pressure. |
|
Series
2000 - Frequency Outputs, Absolute or Gauge Pressure
Transducers |
|

|
- Pressure Ranges:
15 to 500 psia
15 to 200 psig
- 0.01% Accuracy
- 0.0001% Resolution
- Low Power Consumption
- High Stability and Reliability
- Fully Calibrated and
Characterized Quartz Crystal Frequency Outputs
- NIST Traceable - ISO 9001:2000
Quality System
-
Free zero adjustment
- Click here for
absolute and gauge pressure transducer data sheet
|
|
Series
3000 & 4000 - Frequency Outputs, Absolute Pressure
Transducers |
|
 |
- Pressure Ranges 1000 to 40000
psia
- 0.01% Accuracy
- 0.0001% Resolution
- Low Power Consumption
- High Stability and Reliability
-
Onboard
configuration storage - (Series 4000 Only)
- Fully Calibrated and
Characterized Quartz Crystal Frequency Outputs
- NIST Traceable - ISO 9001:2000
Quality System
- Click here for
data sheet
|
|
Series
5300 - Frequency Outputs, Differential Pressure
Transducers |
|
 |
- Pressure Ranges:
0 to 3 psid
0 to 6 psid
0 to 18 psid
- 0.02% Accuracy
- 0.0001% Resolution
- High Stability and Reliability
- High Common Mode Pressure Capability
- Low Power Consumption
- Fully Calibrated and
Characterized Quartz Crystal Frequency Outputs
- Click here for
data sheet
|
|
Series
1000 - RS-232 and RS-485 Outputs, Absolute, Gauge and Differential
Pressure Transmitters |
|

|
- Pressure Ranges:
15 to 10000 psia
15 to 200 psig
0 to 3, 0 to 6, 0-18
psid
- 0.01% Accuracy
- 0.0001% Resolution
- RS-232 and RS-485 Bi-Directional Interfaces
- User Selectable Parameters via
the RS-232 interface, include Resolution, Update Rate, Engineering Units, Sampling
Commands etc. with Supplied
Software
- Low Power Consumption
- High Stability and Reliability
- NIST Traceable - ISO 9001:2000
Quality System
-
Free zero adjustment
- Click here
for a data sheet
|
|
Series 6000 - RS-232 and RS-485 Outputs,
Absolute or Gauge Pressure Transmitters |
|

|
- Pressure Ranges:
15 to 500 psia
15 to 200 psig
- 0.01% Accuracy
- 0.0001% Resolution
- RS-232 and RS-485 Bi-Directional Interfaces
- User Selectable Parameters via
the RS-232 interface include Resolution, Update Rate, Engineering Units, Sampling
Commands etc. with Supplied
Software
- Low Power Consumption
- High Stability and Reliability
- NIST Traceable - ISO 9001:2000
Quality System
-
Free zero adjustment
- Click here
for a data sheet
|
|
Series
9000 - RS-232 and RS-485 Outputs, Absolute Pressure Transmitters |
|

|
- Pressure Ranges from 1000 to
40000 psia
- 0.01% Accuracy
- 0.0001% Resolution
- Low power Consumption
- Bi-Directional RS-232 and RS-485
Interfaces
- User Selectable Parameters via
the RS-232 interface include, Resolution, Update Rate, Engineering Units, Sampling
Commands etc. with Supplied
Software
- NIST Traceable - ISO 9001:2000
Quality System
- Click here
for a data sheet
|
|
Model
745 High Accuracy Laboratory Pressure Standard |
|
 |
|
|
Model
765 High Accuracy Portable Pressure Standard |
|
 |
- 0.008% of Full Scale Accuracy
- Barometric Range Accuracy ±0.08
hPa
- 0.0001% Resolution
- 2 Line User Configurable
Display
- Battery or AC Powered
- Integral Digiquartz®
Transducer
- Average Pressure, Rate, Trend
and Scatter functions
- Front panel Tare,
Hold, Units and Programmable Fast Keys
- RS-232 and USB Interfaces
- User Selectable Parameters
Including Resolution, Update Rate, Engineering Units,
Sampling Commands etc. with Supplied Software
- Integral Data Logger
-
Free zero adjustment
- Click here
to see the details
- Click
here for data sheet
|
©2007