NEW
Digiquartz Interactive 2.0 Software |
|
Download
|
|
Paroscientific has
released a new version of the Digiquartz Interactive software.
Version 2.0 was developed based on years of field experience and customer
feedback with Paroscientific Intelligent products. The new
DQI 2.0 has a completely new interface and other new features combined from
other Digiquartz software, i.e. Digiquartz® Assistant and
Digiquartz Terminal. This eliminates the need to use several
different programs to perform certain tasks.
Features
-
New, user-friendly
interface. Easy access to instrument parameters and
switching between instruments.
-
Ability to setup, configure,
verify, plot and log data within a single program.
-
Support for new
commands and features in new generation Digiquartz® Products.
-
Support for
RS-485, USB and RS-232 interfaces.
-
Improved auto
detect feature remembers instrument IDs, serial numbers and
communication parameters of instruments from previous
communication sessions.
-
Fast switching
between the new instrument menu trees and the terminal page.
-
Improved terminal
page to capture, time-stamp and process data.
-
Easy high-speed
data display and logging.
-
Quick access to
embedded help notes.
-
Simplified
numerical display screen and easy access to diagnostic
parameters.
-
New real-time
plotting and logging panel allows fast access to a graphical
view of real-time data.
All Digiquartz®
Software including Digiquartz® Interactive 2.0 is provided
free-of-charge with every Digiquartz® intelligent product. DQI 2.0 can be
downloaded from our
web site or you can request
it on a Digiquartz® Library CD from Paroscientific.
System Requirements
-
Microsoft Windows
98 Second Edition, Windows NT/2000/XP operating systems
-
PC with 300
megahertz (MHz) or higher processor clock speed recommended;
233-MHz minimum required; Intel Pentium/Celeron family, AMD K6/Athlon/Duron
family, or compatible processor recommended128 megabytes (MB) of
RAM or higher recommended (64 MB minimum supported; may limit
performance and some features)
-
1.5 gigabyte (GB)
of available hard disk space
-
Super VGA (800 ×
600) or higher resolution video adapter and monitor
-
CD-ROM or DVD
drive
-
Keyboard and
Microsoft mouse or compatible pointing device
User
Interface |
|
 |
|
Figure 1.
Digiquartz® Interactive Main Panel |
|
Digiquartz®
Interactive 2.0 (DQI) combines features from other Digiquartz®
Software making it faster to work and exploiting instrument's full
capacity. Switching between the user-friendly Configuration,
Numerical and Graphical Display windows and the Terminal window is
easy. You don't have to exit from one program and launch
another one to do a simple task.
|
 |
|
Figure 2.
Digiquartz® Interactive Configuration Panel
|
|
DQI Configuration
Panel provides user-friendly access to all intelligent instrument
configuration parameters and calibration coefficients in one
location. The parameters are sorted in a tree structure on
the left side of the panel while their values are on the right.
Clicking on each branch of the menu tree provides access to
current values of these parameters and a way to modify/edit these
values. It is not required to know which commands to issue
to an intelligent product to modify a parameter and display its
value. If you are comfortable with the intelligent
instrument communication protocol, you can switch to the terminal
page and issue raw commands to control an intelligent instrument.
On the same panel,
three buttons are available to save the existing configuration of
an instrument or reload a previously saved configuration or print
it. |
 |
|
Figure 3.
Digiquartz® Numerical Display Panel |
|
It is always
convenient to see measurement readings numerically on one page.
For this purpose, DQI has the Numerical Display Panel. On
this panel, diagnostic parameters can be displayed with the click
of a mouse as well for troubleshooting purposes. For Broadband Meteorological Systems,
this is the page where you can display all pressure, temperature
and humidity readings on one page. |
 |
|
Figure 4.
Digiquartz® Graphical Display Panel |
|
It is possible to plot and log
real-time data in DQI 2.0. Plotting and logging are single-channel activities
. This means that one parameter at a time can be
plotted and logged. If you need to plot or log more than one
parameter simultaneously, consider using Digiquartz® Assistant
(DQA). |
|
 |
|
Figure 5.
Digiquartz® Terminal Page |
|
It is easy to switch between
user-friendly configuration panel and the terminal window.
Terminal window is usually for those of you who are more
comfortable with the intelligent instrument communication
commands. This window can also be used to log high speed
data, time stamp them, strip the header off, or switch among
several communication ports easily.
Consult with the built-in help frames
to get familiar with the program features. For questions or comments, please consult our application
support engineers at
support@paroscientific.com. |
|
|
|
©2007 Paroscientific, Inc. |